  • 3. 白光+准直.jpg

White/Collimated + UV Two-channel LED Light Source

ORI-KJ-11-VW40 is a two-channel LED for applications such as microscope illumination, multicolor fluorophore excitation. The color temperature of white LED includes 3000K, 4000K, 5000K, 6500K. While the collimated LED can refer to Collimated LED Light Source KJA-02. UV LED can choose 365nm(>700nW), 405nm(>700nW), 365nm(>2W) .


Product Classification:

LED fluorescence light source


key word:

Two-channel

LED Light Source

White/Collimated + UV

Fluorescent Imaging

fluorescence microscopy


Product Details


ORI-KJ-11-VW40 is a two-channel LED for applications such as microscope illumination, multicolor fluorophore excitation. The color temperature of white LED includes 3000K, 4000K, 5000K, 6500K, while the collimated LED can refer to Collimated LED Light Source ORI-KJ-02  and UV LED can choose 365nm(>700nW), 405nm(>700nW), 365nm(>2W) .

Table1. Parameters Table

Category

White/Collimated + UV Two-channel LED Light Source

Colour Temperature

3000K / 4000K / 5000K / 6500K, details refer to KAYJA’s High-power White LED Light Source ORI-KJ-01

collimated LED Wavelength

Details refer to KAYJA’s Collimated LED Light Source ORI-KJ-02

UV LED wavelength

365nm(>700nW) / 405nm(>700nW) / 365nm(>2W)

Electric Power

28.8 W

Rated Current (CW)

4.8A (not exceeding 5A)

Direct Voltage

6V (Max. 7V)

Spot Size

Dia. 25mm

Angle of divergence

<10°

Lifetime

>10000h

Operating Temperature

0~40

Storage Temperature

-40~70

Dimension

172×147.5×60mm

Weight

1180g

 

Operating Environment

The LED will gradually heat up when using, which will lead to the attenuation of optical power and even shorten the life of the LED. We have excellent heat dissipation structure design, which can prolong the lifetime of LED light source and reduce power loss. Please work in a ventilated environment to avoid overheating, to avoid the decrease of optical power and shorten the lifetime of LED.

LED spectra

Power Supply

We provide the corresponding light source driver, as shown in the figure below. If you are equipped with a constant current drive power supply, please contact us for the pin diagram and strictly follow it when connecting. At the same time, please ensure that the operating current does not exceed the maximum allowable value, provide sufficient forward voltage, and connect the pins correctly.

Maintenance & Service

To avoid damage, do not expose them to sprays, liquids or solvents, and do not open the outer covering. In case of failure, please contact service@oricszlab.com, we will provide you with after-sales service and technical support as soon as possible.

Warning and safety

This LED is not suitable for home interior lighting, must not be operated in explosive atmospheres, and can only be used with shielded connecting cables. The same precautions should be taken if these LEDs are used as an alternative to mercury vapor lamps in microscopes.

UV Warning

The LED emits strong light when working. Part of the LED emission spectrum contains UV components. Do not look directly at the LED light during operation, even a short exposure time may be harmful to the eyes. If direct viewing of the beam is required, protective goggles must be worn to avoid eye injury.

 

 

 

 

 

GET IN TOUCH